Ii NX-8E Control Panel Installation Manual Important information This is the NX-8E Control Panel Installation Manual. This document includes an overview of the product and detailed instructions explaining how to install the NX-8E board inside the enclosure and how to program the control panel.
Advertising
To modular systems. Up to 32 modules can be added to expand the capabilities of the NX-8-CF. Please refer to the current GE Interlogix product catalog for detailed warranty information. ORDERING INFORMATION Minimum system configuration for local and central station protected premise unit UL Commercial Fire applications includes these. Jan 14, 2019 GE Interlogix Caddx About ACT Alarm Computer Technology is a full-service security systems contractor specializing in state-of-the-art burglar alarm systems, fire alarms, CCTV systems, and access control systems. NX-8 KIT Includes NX-8 Control, NX-108E LED Keypad, & 16.5V 40VA Transformer NX-8 NX-8 Control Only NX-108E 8 Zone LED Keypad. And the users manuals for the panel and all the accessories to be included with the system before attempting to install a security system. View and Download GE Interlogix NX-8 installation and startup online. NetworX Series, Commercial Fire Panel. NX-8 Fire Alarms pdf manual download.
NX-8 Control
51
LOC
PG
DESCRIPTION
DEFAULT
DATA
PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
Segment #2
Segment #3
108 34
1
2 3 4 5 6 7 8
Quick Arm
Re-Exit Auto Bypass Silent Panic Audible Panic Auxiliary 1 Auxiliary 2 Multi Keypress Tamper
1
2 3 4 5 6 7 8
LED Extinguish enable
Require user code for bypassing zones Bypass sounder alert AC Power/Low Battery sounder alert Enables Bypass toggle Enables Silent Auto Arm Enables Automatic Instant Reserved
1
2 3 4 5 6 7 8
Open/Close
Bypass Restore Trouble Tamper Cancel Recent Closing Exit Error
109
35 PARTITION 8, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
0
_
Segment #2 (Exit Time #1)
0
_
Segment #3 (Entry Time #2)
0
_
Segment #4 (Exit Time #2)
0
_
110
35 ZONE TYPE 1 ALARM EVENT CODE
8
_
111 Mitchell repair manuals book.
35 ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1 (Circle numbers to program)
1
2
3
4
Fire (enable for fire zone).
24 Hour (enable for non-fire 24 hour zone). Keyswitch zone. Follower (enable for burg zones that are instant during non-entry times).
5
6
7
8
Delay 1 zone (enable to follow Timer 1 Entry/Exit
times). Delay 2 zone (enable to follow Timer 2 Entry / Exit times). Interior (Enable for auto bypass or stay arming). Local Only (enable if zone is not to be reported).
Segment #2 (Circle numbers to program)
1
2 3 4
Keypad audible on alarm.
Yelping siren on alarm. Temporal siren on alarm. Chime.
5
6 7 8
Bypassable.
Group Shunt. Force armable. Entry Guard.
Segment #3 (Circle numbers to program)
1
2 3 4
Fast Loop Response.
Double End of Line Tamper zone. Trouble zone (Day zone). Cross Zone.
5
6 7 8
Dialer Delay zone.
Swinger zone. Restore reporting. Listen-In.
THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF
EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND
THESE DEFAULTS.
112
ZONE TYPE 2 ALARM EVENT CODE
2
_
113
ZONE TYPE 2 CHARACTERISTIC SELECT
2-125-78
114
ZONE TYPE 3 ALARM EVENT CODE
7
_
![]()
115
ZONE TYPE 3 CHARACTERISTIC SELECT
5-1245-5678
116
ZONE TYPE 4 ALARM EVENT CODE
5
_
117
ZONE TYPE 4 CHARACTERISTIC SELECT
45-125-5678
118
ZONE TYPE 5 ALARM EVENT CODE
5
_
119
ZONE TYPE 5 CHARACTERISTIC SELECT
457-125-5678
120
ZONE TYPE 6 ALARM EVENT CODE
4
_
121
ZONE TYPE 6 CHARACTERISTIC SELECT
0-1245-5678
122
ZONE TYPE 7 ALARM EVENT CODE
0
_
123
ZONE TYPE 7 CHARACTERISTIC SELECT
2-0-78
124
ZONE TYPE 8 ALARM EVENT CODE
1
_
125
ZONE TYPE 8 CHARACTERISTIC SELECT
1-13-378
Advertising
Popular Brands
Popular manuals
Advertising
NX-8 Control
20
DEFAULT ZONE TYPES (Configurations)
Zones can be programmed to be one of twenty different zone types (configurations). Zone types # 17 - 20 can be used
for wireless or hardwired zones using European double EOL configuration. The default zone types are listed below.
These zone types can be customized by programming locations 110-149.
DATA
DESCRIPTION OF DEFAULT ZONE TYPES
'1'
DAY ZONE - Instant when system is armed trouble zone when system is disarmed.
'2'
24-HOUR AUDIBLE - Creates an instant yelping siren alarm regardless of the armed state of the control
panel.
'3'
ENTRY/EXIT DELAY 1- A trip will start entry delay 1. The lack of a trip during exit delay will enable the
Automatic Bypass or Instant mode if so programmed.
'4'
FOLLOWER WITH AUTO- BYPASS DISABLED - This zone will be instant when the system is armed
and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not automatically bypass even if enabled in Segment 1 of Location 23.
INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED - This zone will be instant when the system
is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will automatically bypass if enabled in Segment 1 of Location 23.
'6'
INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on.
'7'
24-HOUR SILENT - Creates an instant silent alarm regardless of the armed state of the control panel. It
will not display on the keypad.
'8'
FIRE - This zone will light the Fire LED and sound the temporal siren each time the zone is shorted. It will
also rapidly flash the Fire LED indicating a trouble if the zone is open.
'9'
ENTRY/EXIT DELAY 2- A trip will start entry delay 2. The lack of a trip during exit delay will enable the
Automatic Bypass or Instant mode if so programmed.
'10'
24-HOUR SILENT SUPERVISED- Creates an instant silent alarm regardless of the armed state of the
control panel. It will display on the keypad.
'11'
KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel
that it resides in each time the zone is shorted. Keyswitch arming will report as user #99.
'12'
Caddx Nx 8 User Manual
INTERIOR FOLLOWER WITH 'CROSS ZONE' ENABLED - This zone will be instant when the system
is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a 'Cross Zone' is not being timed it will start a 'Cross Zone' timer. If a 'Cross Zone' is being timed it will create an instant alarm. This zone will automatically bypass when enabled in Segment 1 of Location 23.
'13'
INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED
is off. It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
'14'
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1. This zone will
bypass when the 'Group Bypass' command is entered at the keypad. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed.
'15'
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system
is armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the 'Group Bypass' command is entered at the keypad. This zone will automatically bypass if enabled in Segment 1 of Location 23.
'16'
INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is
tripped and the Armed LED is on. This zone will bypass when the 'Group Bypass' command is entered at the keypad.
'17'
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start entry delay 1. The lack of a trip
during exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a wireless transmitter.
'18'
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant
when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will automatically bypass if enabled in Segment 1 of Location 23. This zone type can be used to enable tamper on a wireless transmitter. Ge Nx 8 User Manual
'19'
INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the
Armed LED is on. This zone type can be used to enable tamper on a wireless transmitter.
'20'
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry delay 2. Jcb 3cx parts manual download. The lack of a trip
during exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a wireless transmitter.
Advertising
Popular Brands
Networx Nx 8 User Manual
Popular manuals
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |